Dental Orthodontics Interproximal Stripping Contra Angle
video

Dental Orthodontics Interproximal Stripping Contra Angle

Interproximal Stripping Contra Angle is Reciprocating IPR System used to obtain clearance and adjust the tooth size by grinding the adjacent enamel to achieve accurate interproximal stripping.
Send Inquiry
Product Introduction

Foshan Wenjian Medical Instrument Co., Ltd. is one of the leading manufacturers and suppliers of dental orthodontics interproximal stripping contra angle in China. With a professional production team, our company is specialized in supplying high quality products for global clients. Please feel free to wholesale advanced dental orthodontics interproximal stripping contra angle from our factory.

 

Product Introduction

Product name

Dental Orthodontics Interproximal Stripping Contra Angle

Model

120014(IPR)

Gear ratio

4:1

Rotation speed: ≥15000RPM/min

≥15000RPM/min

Air pressure

0.3mpa-0.35mpa

Torque

1.595mm-1.6000mm

Noise

≤60db

Torque

30N

Water spray

outer water spray

Connector

E-type

Use

Vertical Reciprocating

Type

Orthodontic Materials

Product Display

1
2

 

Product Feature And Application

Soft sound, ultra quiet

more comfortable for the patient than manual hand stripping

Friendly to doctor, less need to hold rotate instruments

Single-handed, ergonomic design offers optimal tactile control and reduces hand fatigue.

The patient-friendly design prevents gagging and soft tissue irritation.

Flexible strips conform to the natural contours of the teeth to avoid creating sharp corners.

Excessive enamel removal will not happen

Effective for anterior and posterior areas.

Be Autoclavable

applicable for invisible treatment and rapid restoration of enamel

4:1 gear ratio ,low speed operation protects oral safety for patients

Different thickness saw blades(double sided, carborundum material)

90μm-use as a saw for opening contacts

60μm-for reduction

40μm-for contouring

25μm-for finishing

15μm-for per polishing

Product Details

Connecting way for blade holder and slice: lock. Not traditional welding way

Uniquely designed holes on the adjacent surface of the unglazed blade, effectively filter out foreign water and powder during stripping.

Hard material for blade, long lifespan

Anti skid 3D pattern, simple and beautiful, comfortable to hold

Quick connecting way, convenient and time-saving

Product Qualification

Strength-strong manufacturer

We company has a modern production plant,a group of experienced and first-class professionals as well as complete management system

Excellent quality

The products are manufactured based on the principle of ergonomics to provide users with comfortable touch.We adhere to control strictly meticulous design, technology, material selection and production process.

Deliver, shipping and serving

Our Core value -Technology advance, service first

Customized and OEM service are available.

Company Information

001001001

001

Product Packing
Strip contra angel 1 each
IPR Thickness Gauge 1 each
Double sided saw blade:10 pcs, 5 models and 2 pieces each
Removal tool:1 each

FAQ
What circumstances is it suitable to do the adjacent surface to glaze?
1. Relieve crowding, including anterior and posterior teeth.
2. Reducing or improving the gingival space (black triangle) with triangular crown is more suitable for IPR than rectangular teeth
3. Correct the imbalance of upper and lower teeth.Of course, this problem can also be solved by widening smaller teeth with resin or restorations.
4. Reducing the protrusion of single or double jaw and avoiding extraction should be mastered and should not be abused.
What circumstances should not be done adjacent to the glaze?
Of course, these so-called contraindications are all relative.
The tooth is too small, or the crown is abnormal (the widest crown is in the gingival side rather than in the right side)
IPR should not be used when the oral hygiene is poor. Of course, if the oral hygiene is poor, any orthodontic treatment is not suitable.But on the other hand, if the teeth are crowded, it is difficult to do a good job in oral health. After IPR crowding, teeth self-cleaning is better, which is conducive to the maintenance of oral health.
How much is it safe to remove glaze from adjacent surface?
Generally speaking, it is safe to remove less than half of the enamel thickness on the tooth surface. How thick is the enamel on the tooth surface? Everyone and each tooth are different. Most of the enamel thickness is between 0.6 mm and 3 mm. Although there are a lot of data for reference, the effect is limited for each individual.

 

Hot Tags: dental orthodontics interproximal stripping contra angle, suppliers, manufacturers, factory, wholesale, quality, company, supply, professional, Dental Endo Reduction Contra Angle Handpiece supply, Dental Endodontics Reduction Contra Angle Handpiece supply, Professional Dental Endo Reduction Contra Angle Handpiece, Professional Dental Endodontics Reduction Contra Angle Handpiece, Dental Endodontics Reduction Contra Angle Handpiece quality, Dental Endo Reduction Contra Angle Handpiece quality

Send Inquiry

whatsapp

Phone

E-mail

Inquiry